Customization: | Available |
---|---|
Application: | Three Phase Transducer, Single-phase Transducer |
Output Type: | Triple |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
1.Capacity Range:
Single phase 220V(3S): 0.4kw-5.5kw
Three phase 380V(4T): 0.75kw-185kw
|
||||||||
Event | Specifications | |
Maximum frequency | Vector control: 0~600Hz | |
VF control: 0~1200Hz | ||
Carrier frequency | 1k~15kHz: The carrier frequency can be adjusted automatically according to the load characteristics. | |
Input frequency resolution | Digital setting: 0.01Hz | |
Analog setting: Maximum frequency × 0.1% | ||
Control method | Open-loop vector control (SVC), V/F control | |
Starting torque | G-model: 0.5Hz/180% (open-loop vector control) | |
P-model: 0.5Hz/120% (open-loop vector control) | ||
Speed range | 1:200 (open-loop vector control) | |
Speed stabilization accuracy | Open-loop vector control: ≤±0.5% (rated synchronous speed) | |
(Speed control accuracy) | ||
Speed control stability | Open-loop vector control: ≤±0.3% (rated synchronous speed) | |
Torque response | ≤40ms (open loop vector control) | |
Overload capacity | Model G: 150% of rated current for 60 seconds; | |
180% of rated current for 5 seconds | ||
Model P: 120% of rated current for 60 seconds; | ||
150% of rated current for 5 seconds | ||
Torque Increase | Torque increase automatically | |
Torque increase 0.1% to 30.0% manually | ||
V/F curve | Three types: linear; multi-point; squared V/F curve | |
Acceleration/Deceleration curves | Linear or S-curve acceleration and deceleration mode; Four kinds of acceleration and deceleration time; Acceleration and deceleration time range 0.0s~3000.0s | |
DC Brake | DC braking frequency: 0.0Hz~maximum frequency Braking time: 0.0~36.0 seconds | |
Braking action current value: 0.0%~100.0% | ||
Jog control | Point-to-point frequency range: 0.00Hz~50.00Hz; | |
Jog acceleration and deceleration time 0.0s~3000.0s | ||
Simple PLC | Up to 16 speeds via built-in PLC or control terminals | |
Multispeed operation | ||
Built-in PID | Process control closed-loop control system can be realized easily | |
Common DC bus function | Realize the function of DC bus shared by multiple inverters | |
JOG key | Programmable key: Forward and reverse operation/spot operation function selection | |
Textile swing control | Various triangle wave frequency control functions | |
Fast current limit function | Built-in fast current limiting algorithm | |
Reduces the probability of overcurrent reported Improves the anti-interference ability | ||
Timing control | Function: Setting time range 0h~65535h | |
Standardization of keyboard extension cables | Customers may extend the keyboard by using a standard network cable | |
Run | Run command channel | Three types of channels: operator panel given, control terminal given, and serial communication port given. Switchable in various ways |
Frequency source | 10 types of frequency sources: digital, analog voltage, analog current, pulse, and serial port give and take. Switchable in various ways | |
Auxiliary frequency sources | 10 kinds of auxiliary frequency sources. | |
Realization of auxiliary frequency trimming and frequency synthesis flexible. | ||
Input terminal | Standard seven digital input terminals, up to nine digital input terminals (AI1, AI2 can be used as X (DI) terminals), compatible with active PNP or NPN input. | |
Two analog input terminals, of which AI1 can only be used as a voltage input and AI2 can be used as a voltage or current input. | ||
Output terminal | One digital output terminal (bipolar output) | |
Two relay output terminals | ||
Two analog output terminals, can be selected from 0/4mA to 20mA or 0/2V to 10V respectively, which can realize the output of physical quantities such as set frequency, output frequency and rotational speed. | ||
Display and keyboard operation | LED display | Display parameters |
LCD display | Optional, Chinese/English prompts for operation content | |
LCD parameter copy | Quick copying of parameters using the LCD | |
Key lock and function selection | Partial or full locking of keys, defining the scope of action of some keys to prevent misoperation. | |
Protection and Options | Protective function | Power-on motor short-circuit detection, input and output phase loss protection, over-current protection, over-voltage protection, under-voltage protection, over-heating protection, overload protection, etc. |
Optional accessories | LCD operation panel, brake unit, etc. | |
Altitude | Please use at a reduced rate | |
(below 1000 meters, above 1000 meters) | ||
Environmental temperature | -10ºC~+50ºC | |
(please use at a reduced rating 40ºC~50ºC) | ||
Humidity level | Less than 95% RH, no water droplet condensation | |
Vibratory | Less than 5.9 m/s2 (0.6 g) | |
Storage temperature | -20ºC~+60ºC |