Customization: | Available |
---|---|
Application: | High-performance Transducer, Three Phase Transducer, General Transducer, Single-phase Transducer, High Frequency Converter Transducer |
Output Type: | Triple |
Still deciding? Get samples of US$ 100/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Event
|
Specifications | |
Primary control |
Maximum frequency
|
Vector control: 0~600Hz
VF control: 0~1200Hz
|
Carrier frequency
|
1k~15kHz: The carrier frequency can be adjusted
automatically according to the load characteristics.
|
|
Input frequency resolution
|
Digital setting: 0.01Hz
Analog setting: Maximum frequency × 0.1%
|
|
Control method
|
Open-loop vector control (SVC), V/F control
|
|
Starting torque
|
G-model: 0.5Hz/180% (open-loop vector control)
P-model: 0.5Hz/120% (open-loop vector control)
|
|
Speed range
|
1:200 (open-loop vector control
|
|
Speed stabilization accuracy
(Speed control accuracy)
|
Open-loop vector control: ≤±0.5% (rated synchronous speed)
|
|
Speed control stability
|
Open-loop vector control: ≤±0.3% (rated synchronous speed)
|
|
Torque response
|
≤40ms (open loop vector control)
|
|
Overload capacity
|
Model G: 150% of rated current for 60 seconds;
180% of rated current for 5 seconds
Model P: 120% of rated current for 60 seconds;
150% of rated current for 5 seconds
|
|
Torque Increase
|
Torque increase automatically
Torque increase 0.1% to 30.0% manually
|
|
V/F curve
|
Three types: linear; multi-point; squared V/F curve
|
|
Acceleration/Deceleration
curves
|
Linear or S-curve acceleration and deceleration mode; Four
kinds of acceleration and deceleration time; Acceleration and
deceleration time range 0.0s~3000.0s
|
|
DC Brake
|
DC braking frequency: 0.0Hz~maximum frequency Braking
time: 0.0~36.0 seconds
Braking action current value: 0.0%~100.0%
|
|
Jog control
|
Point-to-point frequency range: 0.00Hz~50.00Hz;
Jog acceleration and deceleration time 0.0s~3000.0s
|
|
Simple PLC
Multispeed operation
|
Up to 16 speeds via built-in PLC or control terminals
|
|
Built-in PID
|
Process control closed-loop control system can be realized
easily
|
|
Automatic Voltage Regulation
(AVR)
|
Keep the output voltage constant when the grid voltage
changes automatically
|
|
Torque limiting and control
|
"Digger" feature: torque limiting during operation to prevent
frequent overcurrent trips automatically;
Closed-loop vector mode for torque control
|
|
Power-up peripherals safety
self-test
|
Power-on safety detection of peripheral devices such as
grounding, short-circuiting, etc. can be realized
|
|
Customized |
Common DC bus function
|
Realize the function of DC bus shared by multiple inverters
|
JOG key
|
Programmable key: Forward and reverse operation/spot
operation function selection
|
|
Textile swing control
|
Various triangle wave frequency control functions
|
|
Fast current limit function
|
Built-in fast current limiting algorithm
Reduces the probability of overcurrent reported Improves
the anti-interference ability
|
|
Timing control
|
Function: Setting time range 0h~65535h
|
|
Standardization of keyboard
extension cables
|
Customers may extend the keyboard by using a standard
network cable
|
|
Run |
Run command channel
|
Three types of channels: operator panel given, control
terminal given, and serial communication port given.
Switchable in various ways
|
Frequency source
|
10 types of frequency sources: digital, analog voltage, analog
current, pulse, and serial port give and take. Switchable in
various ways
|
|
Auxiliary frequency sources
|
10 kinds of auxiliary frequency sources.
Realization of auxiliary frequency trimming and frequency
synthesis flexible.
|
|
Input terminal
|
Standard seven digital input terminals, up to nine digital input
terminals (AI1, AI2 can be used as X (DI) terminals),
compatible with active PNP or NPN input.
Two analog input terminals, of which AI1 can only be used as a
voltage input and AI2 can be used as a voltage or current
input.
|
|
Output terminal
|
One digital output terminal (bipolar output)
Two relay output terminals
Two analog output terminals, can be selected from 0/4mA to
20mA or 0/2V to 10V respectively, which can realize the
output of physical quantities such as set frequency, output
frequency and rotational speed.
|
|
Display and keyboard operation |
LED display
|
Display parameters
|
LCD display
|
Optional, Chinese/English prompts for operation content
|
|
LCD parameter copy
|
Quick copying of parameters using the LCD
|
|
Key lock and function
selection
|
Partial or full locking of keys, defining the scope of action of
some keys to prevent misoperation
|
|
Protection and options |
Protective function
|
Power-on motor short-circuit detection, input and output
phase loss protection, over-current protection, over-voltage
protection, under-voltage protection, over-heating protection,
overload protection, etc.
|
Optional accessories
|
LCD operation panel, brake unit, etc.
|
|
Environment |
Location
|
Indoors, out of direct sunlight, free of dust, corrosive gases,
flammable gases, oil mist, water vapor, dripping water or salt,
etc.
|
Altitude
|
Please use at a reduced rate
(below 1000 meters, above 1000 meters)
|
|
Environmental temperature
|
-10ºC~+50ºC
(please use at a reduced rating 40ºC~50ºC)
|
|
Humidity level
|
Less than 95% RH, no water droplet condensation
|
|
Vibratory
|
Less than 5.9 m/s 2 (0.6 g)
|
|
Storage temperature
|
-20ºC~+60ºC
|
|
Contamination level
|
2
|
|
Product Standard |
Product implementation of
safety standards
|
IEC 61800-5-1:2007
|
Product implementation of
EMC standards
|
IEC 61800-3:2005
|